USD

AddressCompany:Shenzhen Tuoli Electronic Technology Co.,Ltd.
Address:Floor 6, Building B, Baifuli Industrial Park, Shanghenglang Industrial Zone,
Dalang Street, Longhua District, Shenzhen
Service Hotline:008618899777586 (WhatsApp)
E-mail:Service@tuolitech.com


Fluke T+ Electrical Tester Safer than traditional solenoid testers and fully compliant with NFPA 70E

Copy and share this link on social network or send it to your friends

Copy

Fluke T+ Electrical Tester Safer than traditional solenoid testers and fully compliant with NFPA 70E Item NO.: 548613

Write a Review
US$ 64.40
Quantity:
Stock ( 9999999 )
Shipping Cost:
Estimate Shipping Cost
Product Name Fluke T+ Electrical Tester Safer than traditional solenoid testers and fully compliant with NFPA 70E
Item NO. 548613
Measuring testers Electrical tester
Weight 1.2 kg = 2.6455 lb = 42.3288 oz
Category Phone repair tools
Tag T , T+ , multimeter , Electrical Tester , electronic tester , digital tester , electric tester , Fluke tester , Fluke T+
Brand FLUKE
Creation Time 2019-09-11

Product overview: Fluke T+ Electrical Tester


Safer than traditional solenoid testers and fully compliant with NFPA 70E*

The T+ Electrical Testers offer all the functionality that electricians look for in volt meters and voltage and continuity testers:

  • Three ways to detect AC/DC voltage: light, sound, and vibration
  • Added functionality of a GFCI trip and continuity beeper, plus the convenience of a built-in flashlight

Safer than traditional solenoid testers:

  • Solid-state tester design
  • CAT IV 600 V, CAT III 1000 V rated
  • Complies with NFPA 70E*

The ruggedness and reliability that customers have come to expect from Fluke

* When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment.


Specifications: Fluke T+ Electrical Tester

Specifications
Temperature Operating -10°C to 55°C (14°F to 131°F)
Storage -30°C to 60°C (-22°F to 140°F)
Relative humidity 90% 0°C to 30°C (32°F to 86°F)
75% 30°C to 40°C (86°F to 104°F)
45% 40°C to 50°C (104°F to 122°F)
Altitude Operating 2,000 m (approx. 6,561.6 ft)
Storage 10,000 m (approx. 32,808.4 ft)
Battery type/life AAA (2); 40 hours
Shock, vibration Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument
Safety ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV
Compliance to NFPA 70E1
AC bandwidth 45 Hz to 66 Hz
Maximum working voltage 1000 V AC/DC
Maximum measurable voltage 600 V AC/DC
Duty cycle Indefinitely for voltages up to 240 V
For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off
For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s
Voltage hazard LED LEDs turn on at voltages > 30 V AC/DC ± 35%
LED voltage indication levels 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V
LEDs LEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100%
LCD resolution 0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V
GFCI test current 100 V - 150 V @ 6 mA - 9 mA AC, 150 V - 240 V < 12 mA
Standard input test current < 5 mA
Size (H x W x L) 1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm )
Weight 9.9 oz (0.28 kg)
1. When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment.



No related record found