USD

AddressCompany:Shenzhen Tuoli Electronic Technology Co.,Ltd.
Address:Floor 6, Building B, Baifuli Industrial Park, Shanghenglang Industrial Zone,
Dalang Street, Longhua District, Shenzhen
Service Hotline:008618899777586 (WhatsApp)
E-mail:Service@tuolitech.com


Fluke T5-1000 / T5-600 T6-600 /T6-1000  Voltage Continuity and Current Tester

Copy and share this link on social network or send it to your friends

Copy

Fluke T5-1000 / T5-600 T6-600 /T6-1000 Voltage Continuity and Current Tester Item NO.: 542838

Write a Review
US$ 80.06
Model:
T5-600 T5-1000 T6-600 T6-1000
Quantity:
Stock ( 39999996 )
Shipping Cost:
Estimate Shipping Cost
Product Name Fluke T5-1000 / T5-600 T6-600 /T6-1000 Voltage Continuity and Current Tester
Item NO. 542838
Measuring testers Voltage tester, Current tester/Ammeter
Weight 1.8 kg = 3.9683 lb = 63.4931 oz
Category Phone repair tools
Tag T5-1000 , T5-600 , T6 , T5 , T6-600 , T6-1000 , voltage tester , Fluke voltage tester , current tester , current meter , Fluke current tester , vltage meter
Brand FLUKE
Creation Time 2019-09-09

Specifications: Fluke T6-1000 Electrical Tester

Measurement Specifications
Function Requires test leads Range Resolution Accuracy[1]
FieldSense
ac voltage true-rms
No 1000 V 1 V ± (3 % + 3 counts) 45 Hz - 66 Hz[2][3]
FieldSense
ac current true-rms
No 200.0 A 0.1 A ± (3% + 3 counts) 45 Hz - 66 Hz
FieldSense
frequency (Hz)
No 45 Hz – 66 Hz 1 Hz ± (1% + 2 counts)[3]
Volts ac true-rms Yes 1000 V 1 V ± (1.5% + 2 counts) 45 Hz - 66 Hz
Volts dc Yes 1000 V 1 V ± (1% + 2 counts)
Resistance Yes 2000 Ω 1 Ω ± (1% + 2 counts)
Yes 20.00 kΩ 0.01 kΩ
Yes 100.0 kΩ 0.1 kΩ
Safety 1000 V CAT III
600 V CAT IV

Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

 
General Specifications
Calibration 1-year calibration cycle
Dimensions 61.1 x 259.3 x 43.8 mm
Jaw opening 17.8 mm
Weight 0.35 kg (0.78 lb)
Temperature Operating -10 °C to +50 °C (14 °F to 122 °F)
Storage -30 °C to +60 °C (-22 °F to +140 °F)
Altitude Operating 2,000 m (6,562 feet)
Storage 10,000 m (32,808 feet)
Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
0.1 x (specified accuracy) / °C for <18°C or >28 °C
Safety IEC/EN 61010-1: Pollution Degree 2
Electromagnetic Environment IEC/EN 61326-1: Portable