Detailed Specifications
|
AC Voltage
|
Range 1
|
Resolution
|
Accuracy 234
|
Accuracy 234
|
45 Hz to 500 Hz
|
500 Hz to 1 kHz
|
600.0 mV
|
0.1 mV
|
1.0% + 3
|
2.0% + 3
|
6.000 V
|
0.001 V
|
60.00 V
|
0.01 V
|
600.0 V
|
0.1 V
|
1000 V
|
1 V
|
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
|
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
|
Function
|
Range
|
Resolution
|
Accuracy
|
mV
|
600.0 mV
|
0.1 mV
|
0.09% + 2
|
V
|
6.000 V
|
0.001 V
|
0.09% + 2
|
60.00 V
|
0.01 V
|
600.0 V
|
0.1 V
|
1000 V
|
1 V
|
0.15% + 2
|
Ω
|
600 Ω
|
1 Ω
|
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
|
Ω
|
600.0 Ω
|
0.1 Ω
|
0.5% + 2
|
6.000 kΩ
|
0.001 kΩ
|
0.5% + 1
|
60.00 kΩ
|
0.01 kΩ
|
60.00 kΩ
|
0.1 kΩ
|
600.0 kΩ
|
0.001 MΩ
|
50.00 MΩ
|
0.01 MΩ
|
1.5% + 3
|
Diode test
|
2.000 V
|
0.001 V
|
1% + 2
|
µF
|
1000 nF
|
1 nF
|
1.2% + 2
|
10.00 μF
|
0.01 μF
|
100.0 μF
|
0.1 μF
|
9999 μF1
|
1 μF
|
10% typical
|
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
|
AC and DC Current
|
Function
|
Range 1
|
Resolution
|
Accuracy
|
mA AC
(45 Hz to 1 kHz)
|
60.00 mA
|
0.01 mA
|
1.5% + 3
|
400.0 mA 3
|
0.1 mA
|
mA DC 2
|
60.00 mA
|
0.01 mA
|
0.5% + 3
|
400.0 mA 3
|
0.1 mA
|
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
|
Frequency
|
Range
|
Resolution
|
Accuracy 1
|
99.99 Hz
|
0.01 Hz
|
0.1% + 1
|
999.9 Hz
|
0.1 Hz
|
9.999 kHz
|
0.001 kHz
|
99.99 kHz
|
0.01 kHz
|
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
|
Input Characteristics
|
Function
|
Overload
protection
|
Input impedance
(nominal)
|
Common mode rejection ratio (1 kΩ unbalance)
|
Normal mode rejection
|
|
1100 Vrms
|
> 10 MΩ < 100 pF
|
> 120 dB at DC, 50 Hz or 60 Hz
|
> 60 dB at 50 Hz or 60 Hz
|
|
1100 Vrms
|
> 10 MΩ < 100 pF
|
> 60 dB, DC to 60 Hz
|
|
|
1100 Vrms
|
> 10 MΩ < 100 pF
|
> 120 dB at DC, 50 Hz or 60 Hz
|
> 60 dB at 50 Hz or 60 Hz
|
Open circuit test voltage
|
Full scale voltage
|
Typical short circuit current
|
To 6 MΩ
|
50 MΩ
|
|
1100 Vrms
|
< 2.7 VDC
|
< 0.7 VDC
|
< 0.9 VDC
|
< 350 mA
|
|
1100 Vrms
|
< 2.7 VDC
|
2.000 VDC
|
< 1.1 mA
|
mA Function
|
Overload Protection
|
Fused, 44/100 A, 1000 V FAST Fuse
|
Overload
|
600 mA overload for 2 minutes maximum, 10 minutes rest minimum
|
MIN/MAX Recording Accuracy
|
DC functions
|
The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
|
AC functions
|
The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
|
General Specifications
|
Maximum voltage between any terminal and earth ground
|
1000 VDC or AC rms
|
Ω fuse protection from A inputs
|
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
|
Display (LCD)
|
Update rate
|
4/sec
|
Volts, amps, ohms
|
6000 counts
|
Frequency
|
10,000 counts
|
Capacitance
|
1,000 counts
|
Battery type
|
Three AA Alkaline batteries, NEDA 15A IEC LR6
|
Battery life
|
250 hours minimum
|
RF communications
|
2.4 GHZ ISM Band
|
RF communication range
|
Open air, unobstructed
|
Up to 20 m
|
Obstructed, sheetrock wall
|
Up to 6.5 m
|
Obstructed, concrete wall, or steel electrical enclosure
|
Up to 3.5 m
|
Temperature
|
Operating
|
-10°C to 50°C
|
Storage
|
-40°C to 60°C
|
Temperature coefficient
|
0.1 x (specified accuracy) / °C (<18°C or >28°C)
|
Relative humidity
|
0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
|
Altitude
|
Operating
|
2,000 m
|
Storage
|
12,000 m
|
Electromagnetic compatibility
EMI, RFI, EMC, RF
|
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
|
Safety compliance
|
ANSI/ISA 61010-1 / (82.02.01)
|
3rd edition
|
CAN/CSA-C22.2 No 61010-1-12
|
3rd edition
|
UL 61010-1
|
3rd edition
|
IEC/EN 61010-1
|
2010
|
Certifications
|
CSA, FCC, CE
|
Ingress Protection (IP) rating
|
IP54
|
Pollution degree
|
2
|
Size (H x W x L)
|
4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
|
Weight
|
340 g (12 oz)
|
Warranty
|
Three years
|
Not compatible with Fluke CNX test tools
|
No related record found