USD

AddressCompany:Shenzhen Tuoli Electronic Technology Co.,Ltd.
Address:Floor 6, Building B, Baifuli Industrial Park, Shanghenglang Industrial Zone,
Dalang Street, Longhua District, Shenzhen
Service Hotline:008618899777586 (WhatsApp)
E-mail:Service@tuolitech.com


Fluke 368 FC Leakage Current Clamp Meter

Copy and share this link on social network or send it to your friends

Copy

Fluke 368 FC Leakage Current Clamp Meter Item NO.: 546852

Write a Review
US$ 390.40
Quantity:
Stock ( 9999999 )
Shipping Cost:
Estimate Shipping Cost
Product Name Fluke 368 FC Leakage Current Clamp Meter
Item NO. 546852
Measuring testers Current tester/Ammeter, Clamp meter
Weight 1.8 kg = 3.9683 lb = 63.4931 oz
Category Phone repair tools
Tag 368 , 368fc , clamp meter , Fluke clamp meter , Fluke tester , current tester , current meter , Fluke meter , Fluke 368 meter , 368 clamp meter , leakage current meter
Brand FLUKE
Creation Time 2019-09-10

Product overview: Fluke 368 FC Leakage Current Clamp Meter


Reduce downtime – Find leakage currents without taking equipment offline.

The Fluke 368 FC true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line.

The Fluke 368 FC has a large 40 mm diameter jaw for work with large conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.

The 368 FC also offers wireless data connectivity via Fluke Connect. As part of Fluke Connect — the industry’s largest system of software and more than 40 wireless test tools — the 368 FC allows you to track changes in leakage current over time, helping to identify potential problems before they turn into major failures.


Specifications: Fluke 368 FC Leakage Current Clamp Meter

Electrical Specifications
Measurement function Alternating current
AC ampere range 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
mA / A: manual selection
3 mA / 30 mA / 300 mA: automatic selection
3 A / 30 A / 60 A: automatic selection
Range / Resolution 3 mA¹ / 0.001 mA
30 mA / 0.01 mA
300 mA / 0.1 mA
3 A / 0.001 A
30 A / 0.01 A
60 A / 0.1 A
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)² 3 mA – 30 A
60 A
1% + 5 digits
2% + 5 digits
Frequency 40 Hz to 1 kHz
Crest Factor 3
After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%.
¹The minimum value is 10 μA rms.
²Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1
Physical
Display (LCD) Digital readout: 3300 count
Display refresh rate 4 times / sec
Maximum conductor diameter 40 mm
Dimensions 234 x 101 x 46 mm
Weight 500 g
Battery 2 AA, IEC LR6, NEDA 15A, alkaline
Battery life Expected battery life, without using backlight and spotlight, is more than 150 hours
Automatic shut-down Meter automatically shuts down after 15 minutes of inactivity
Safety and Environmental Specifications
General safety IEC 61010-1: Pollution Degree 2
Measurement safety IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity Non-condensing (<10 °C)
90% relative humidity (10 °C to 30 °C)
75% relative humidity (30 °C to 40 °C)
45% relative humidity (40 °C to 50 °C)
Protection class IEC 60529: IP30 (jaw closed)
Operating altitude 2000 m
Storage altitude 12000 m
Current sensor action category IEC 61557-13: Class 2, ≤30 A / m
Electromagnetic compatibility (EMC)
International
IEC 61326-1 Industrial Electromagnetic Environment
CISPR 11 Group 1 Class B
Group 1 Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential.
Class B Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements.
Korea (KCC): A type of equipment (radio and communication equipment industry)
Class A This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment.
USA (FCC): 47 CFR 15 B Subpart. In accordance with section 15.103 provides that the products are considered tax-free device.



No related record found