USD

AddressCompany:Shenzhen Tuoli Electronic Technology Co.,Ltd.
Address:Floor 6, Building B, Baifuli Industrial Park, Shanghenglang Industrial Zone,
Dalang Street, Longhua District, Shenzhen
Service Hotline:008618899777586 (WhatsApp)
E-mail:Service@tuolitech.com


Fluke A3000 FC Wireless AC Current Clamp Kit wireless test tools

Copy and share this link on social network or send it to your friends

Copy

Fluke A3000 FC Wireless AC Current Clamp Kit wireless test tools Item NO.: 543447

Write a Review
US$ 415.31
Quantity:
Stock ( 9999999 )
Shipping Cost:
Estimate Shipping Cost
Product Name Fluke A3000 FC Wireless AC Current Clamp Kit wireless test tools
Item NO. 543447
Measuring testers Current tester/Ammeter, Multimeter
Weight 1.8 kg = 3.9683 lb = 63.4931 oz
Category Phone repair tools
Tag 3000 , A3000 , A3000 FC , current tester , Fluke 3000 , Fluke A3000 , current clamp meter , current clamp kit , wireless test tools
Brand FLUKE
Creation Time 2019-09-09

Product overview: Fluke a3000 FC Wireless AC Current Clamp Kit


The Fluke a3000 FC Wireless AC Current Clamp Kit is part of the Fluke Connect® team of wireless test tools

Connect the a3000 FC Wireless AC Current Clamp Module to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.

You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect™ modules as a system for multiple measurements.

From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless AC Current Clamp Module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.

Now you can take readings on moving machinery, with only the measurement module in harm’s way.


Specifications: Fluke a3000 FC Wireless AC Current Clamp Kit

Fluke 3000 FC Series Wireless Multimeter

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading] + [Number of least significant digits]).

AC Voltage
Range¹ / resolution   600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy234 45 Hz to 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. All AC voltage ranges are specified from 1% of range to 100% of range. 
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor 3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. 
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
mV Range / resolution 600.0 mV / 0.1 mV
Accuracy 0.09% + 2
V Range / resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V 
1000 V / 1 V
Accuracy 0.09% + 2
0.15% + 2
))) Range / resolution 600 Ω / 1 Ω
Accuracy Meter beeps at
Ω Range / resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range / resolution 2.000 V / 0.001 V
Accuracy 1% + 2
µF
Range / resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy 1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
mA AC 
(45 Hz to 1 kHz)
Range1 / resolution 60.00 mA / 0.01 mA
400.0 mA3/ 0.1 mA
Accuracy 1.5% + 3
mA DC2 Range1 / resolution 60.00 mA / 0.01 mA
400.0 mA3/ 0.1 mA
Accuracy 0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range. 
2. Input burden voltage (typical): 400 mA input 2 mV/mA. 
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy1 0.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Overload protection 1100 Vrms
Input impedance (nominal) > 10 MΩ
Common mode rejection ratio 
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection > 60 dB at 50 Hz or 60 Hz
Overload protection 1100 Vrms
Input impedance (nominal) > 10 MΩ
Common mode rejection ratio 
(1 kΩ unbalance)
> 60 dB, DC to 60 Hz
Normal mode rejection > 60 dB at 50 Hz or 60 Hz
Overload protection 1100 Vrms
Input impedance (nominal) > 10 MΩ
Common mode rejection ratio 
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection > 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Overload protection 1100 Vrms
Input impedance (nominal)
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
Typical short circuit current
Overload protection 1100 Vrms
Input impedance (nominal)
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
2.000 VDC
Typical short circuit current
mA Function
Overload protection Fused, 44/100 A, 1000 V FAST Fuse
Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions ±12 counts for changes > 350 mS in duration.
AC functions ±40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground 1000 VDC or AC rms
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate 4/sec
Volts, amps, ohms 6000 counts
Frequency 10,000 counts
Capacitance 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m
Temperature Operating -10°C to 50°C
Storage -40°C to 60°C
Temperature coefficient 0.1 x (specified accuracy) / °C ( 28°C)
Relative humidity 0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
Altitude Operating 2,000 m
Storage 12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition 
IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution Degree 2
Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight 340 g (12 oz)
Warranty Three years
Not compatible with Fluke CNX test tools

Fluke a3000 FC Wireless AC Current Clamp Module

Specifications
Range 0.5 A to 400.0 A
Resolution 0.1 A
Accuracy 400.0 A: 2% ±5 digits (10 Hz to 100 Hz), 2.5% ±5 digits (100 Hz to 500 Hz)
Inrush Max displayed reading 999.9A
Crest factor (50 Hz / 60 Hz) 3 at 500 A
2.5 at 600 A
1.42 at 1000 A
Add 2% for C.F. > 2
LCD w/backlight 3½ digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient Add 0.1 x (specified accuracy) / °C ( 28°C)
Operating humidity 90% at 35°C
75% at 40°C
45% at 50°C
Altitude Operating 2,000 m
Storage 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2
Safety rating CAT III 600 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP30
Pollution Degree 2
Jaw opening 34 mm (1.33 in)
Size (H x W x D) 20.3 x 7.49 x 3.55 cm (8 x 2.95 x 1.4 in)
Weight .22 kg (8 oz)
Warranty Three years
Not compatible with Fluke CNX test tools



No related record found